Do not confuse the air conditioning , heating and ventilation of this Kia Pride. Heating and air conditioning are systems that can lower or increase the air temperature. The very first thanks to the heat produced from the engine block, and the second with the help of a fluid refrigerant . Ventilation is the totality of channels and devices that give the possibility of air to get inside. The fundamental component will be kicker which sends air into your cabin. If the air barely or not at all arrives, it is probably a ventilation problem. We will see through this post how ventilation works, in order to better perceive the malfunctions and assimilate how to remedy them.
How ventilation works on a Kia Pride
The ventilation is used first to regenerate the air inside the cabin of this Kia Pride. Regarding the blower, it is often made of a resistor, a turbine, and a motor. The more the total resistance of the circuit is reduced, the faster the turbine runs. By turning the switch in the vehicle, the resistance is therefore lowered.
Kia Pride: common ventilation issues
Dirty air ducts
When the ventilation works but little air arrives in the cabin of this Kia Pride, it is possible that the air shutters are obstructed. Thanks to a screwdriver flat, do not hesitate to remove the air shutter covers. Just take a look in if they are cluttered. When this is happening do not hesitate to clean them, but also the valves.
Dirty cabin filter
In case you perceive fumes and your ventilation is weak, the concern must certainly come from the cabin filter of this Kia Pride. It clogs and piles up bacteria as time goes by. It is quite normal that it is clogged, it is there to purify the air that reaches us. There is no recommendation from the manufacturer as to when to change it. It is only advisable to dismantle it, check its condition. When it is completely dirty, it will be necessary to replace it.
Resistance of the blower HS
When the ventilation adjustment of the Kia Pride works poorly, if at all, it is certainly linked to the resistance. This resistance is used to raise the voltage to amplify the speed of this turbine. Inconsistent operation of your ventilation may be due to a concern for resistance. This microchip is difficult to repair. It needs to be replaced.
HS blower motor
There are two fairly recurring malfunctions on the blower. The brushes are deteriorated. Over the years, these can wear out and generate electrical faults. Your kicker may work in a hazardous manner, or may not work at all. It is also possible that the concern comes from bearings of the motor. When the ventilation makes a sharp noise, like a rusty mechanism, it can happen that its bearings lack lubrication. We invite you to comment on this post in case your concern is different to help other readers. Good road!