Do not confuse the air conditioning , heating and ventilation of the Suzuki Carry. Heating and air conditioning are systems that offer the possibility of reducing or increasing the air temperature. The very first passing through the heat emitted by the engine, and the second with the help of a liquid refrigerant . Your ventilation is the set of channels and systems that give the opportunity for air to enter the passenger compartment. The main component is kicker which emits air inside your cabin. If there is barely or no air at all, it is likely a ventilation problem. We will see in this file how a breakdown works, so as to better discern the problems and understand how to resolve it.
How a ventilation works on a Suzuki Carry
The ventilation is primarily used to circulate the air in the interior of the Suzuki Carry. Regarding the blower, it is often made of a resistor, a turbine, and a motor. The lower the integral resistance of the electrical system, the faster the turbine turns. By turning the button in the vehicle, the resistance is reduced.
Suzuki Carry: usual ventilation problems
Dirty air ducts
If the ventilation turns but little air reaches the interior of the Suzuki Carry, it is possible that your air shutters are obstructed. With the aid of screwdriver flat, do not hesitate to remove the valves from the air vents. It will suffice to check in if these are obstructed. When this is the case, do not hesitate to scour them, but also the shutters.
Dirty cabin filter
If you ever see effluxes and your ventilation lacks intensity, the problem is certainly due to the cabin filter of the Suzuki Carry. The latter is blocked and piled up bacteria with time. It is completely normal that this one is clogged, it is there to filter the air which reaches us. There is no manufacturer's recommendation as to when to replace it. We simply advise you to dismantle it, check its condition. In case it is really dirty, it will be better to replace it.
Resistance of the blower HS
In case the ventilation controls of the Suzuki Carry do not work well, or even really do not, it is certainly related to the resistance. The resistance increases the voltage to amplify the speed of this turbine. A strange malfunction of your ventilation may be related to a resistance problem. This little microchip is difficult to troubleshoot. It will have to be replaced.
HS blower motor
There are two fairly regular problems with the kicker. The brushes are deteriorated. Over time, they may wear out and produce electrical faults. The fan can operate very randomly, or even not activate at all. In addition, the problem may arise from bearings of the motor. In the event that the ventilation makes a sharp noise, comparable to a rusty mechanism, it happens that the bearings lack lubrication. We invite you to comment on this file if your problem is different to help users. Enjoy the road!