Do not confuse the air conditioning , heating and ventilation of the Toyota Ft-hs. Heating and air conditioning happen to be devices that can reduce or increase the air temperature. The very first thanks to the heat emitted from the engine, and the other with the help of a liquid refrigerant . Ventilation is all the channels and devices that will allow the air to reach the interior. The main element is the kicker which emits air within your vehicle. If very little or no air is coming in, it is most likely a ventilation problem. We will see in this guide how a ventilation works, so as to better perceive the concerns and assimilate by what means to remedy them.
How a ventilation works on a Toyota Ft-hs
The primary purpose of ventilation is to circulate the air in the cabin of the Toyota Ft-hs. Regarding the blower, it is usually composed of a resistance, a turbine, and a motor. The more the integral resistance of the electrical system is lowered, the faster the turbine runs. By turning the switch in the vehicle, the resistance is therefore lowered.
Toyota Ft-hs: frequent ventilation problems
Dirty air ducts
If the ventilation ever works but very little air is getting into the cabin of the Toyota Ft-hs, it is possible that the air flaps are clogged. Using a screwdriver flat, it is possible to remove the flaps from the air vents. Just check inside if they are crowded. If this is what happens, it is possible to dust them off, as well as the valves.
Dirty cabin filter
If you ever feel efflux and this ventilation is poor, the problem is probably with the cabin filter of the Toyota Ft-hs. This gets blocked and piles up bacteria as time goes by. It is still really common that it is dirty, it is there to clarify the air which reaches us. There is no recommendation from the manufacturer as to when to replace it. We simply advise you to remove it, check its condition. If the latter is completely clogged, it will need to be changed.
Resistance of the blower HS
If the ventilation buttons on your Toyota Ft-hs ever work badly, if at all, it is probably due to the resistance. The resistance allows to increase the voltage to be able to increase the speed of the turbine. A bizarre malfunction of this ventilation is probably due to a resistance problem. This little microchip is difficult to troubleshoot. It will have to be changed.
HS blower motor
There are two relatively recurring issues with the kicker. The brushes may be damaged. Over time, they will be able to wear out and produce false contact. The fan may run haphazardly, or not run at all. It also happens that the problem comes from bearings of the fan motor. If the ventilation makes a high-pitched noise, comparable to rusty mechanics, the bearings may need lubrication. We invite you to comment on this guide if your problem is different to help our readers. Good walk!